In short
The Batteries Regulation lets you choose: host the battery passport yourself or give another operator written authorisation (Article 77(4)). In both cases the responsibility stays with you. The difference is who builds, secures, updates and keeps the system available, and what happens when your company changes.
In-house or outsourced: the differences
| What the Regulation requires | In-house | Outsourced |
|---|---|---|
| A passport per battery, updated during use and on status changes (Art. 77(1) and (7), Annex XIII point 4) | Your own system and operations | Part of the service |
| Available until recycling, also if you cease to exist (Art. 77(8), Art. 78(e)) | Server depends on your company | Hosting arranged independently of your company |
| Open standards, QR code and identifier per ISO/IEC 15459 (Art. 77(3) and (5)) | Build the knowledge yourself | Knowledge of the service provider |
| Access rights per audience (Art. 77(2), Art. 78(b) and (f)) | Build user management yourself | Part of the service |
| Security, integrity and fraud prevention (Art. 78(g) and (h)) | Own security and monitoring | Set up once for all customers |
| Changing rules and standards (Art. 77(2), (3) and (9)) | Follow and implement yourself | Provider follows and adapts |
| Legal responsibility (Art. 77(4)) | With you | Stays with you |
Eight arguments from the Batteries Regulation
1. A continuing service, not a one-off document
Every individual battery needs its own passport (Article 77(1)). For batteries in use, it includes data on state of health, status and use, such as charging cycles and negative events (Annex XIII, point 4). After repurposing or remanufacturing, a new passport is linked to the original one (Article 77(7)). Doing it yourself means running an IT system for years next to your actual business.
2. Available even if your company no longer exists
The passport must remain available after the responsible economic operator ceases to exist or ceases its activity in the Union (Article 78, point (e)). It ends only after recycling (Article 77(8)). A server of your own shares the fate of your company: after insolvency, a takeover or a discontinued product line, someone still has to host the passports. Outsourcing lets you arrange hosting independently of your own business and record it in a contract.
3. Open standards, QR code and identifiers according to the standards
Passport data must be based on open standards, interoperable, machine-readable and searchable, without vendor lock-in (Article 77(5)), and fully interoperable with other digital product passports (Article 78, point (a)). The QR code and unique identifier must comply with the ISO/IEC 15459 series or their equivalent (Article 77(3)); the European standards EN 18219 and EN 18220 work this out. That is specialist knowledge you do not have to build yourself.
4. Access rights per audience
Part of the passport is public, part is limited to persons with a legitimate interest such as repairers and recyclers, and part to notified bodies, market surveillance authorities and the Commission (Article 77(2), Annex XIII). Access and changes must be restricted accordingly (Article 78, points (b) and (f)). That requires a system with user management and authentication, not a PDF on a website.
5. Security and integrity of the data
The Regulation requires data authentication, reliability and integrity, and a high level of security and privacy that avoids fraud (Article 78, points (g) and (h)). Backups, logging, updates and monitoring are ongoing work. A service provider organises them once for all its customers.
6. The rules are still changing
The Commission may amend Annex XIII in view of technical and scientific progress (Article 77(2)), replace the standards for the QR code and identifier (Article 77(3)) and specify by implementing acts who has a legitimate interest (Article 77(9)). If you build it yourself, you have to follow and implement every change yourself.
7. Outsourcing is provided for by law and your data is protected
Article 77(4) allows written authorisation and Article 78, point (c), mentions storage by authorised operators. An authorised operator may not sell, re-use or process the data beyond what the service requires (Article 78, point (d)). Your commercially sensitive battery data is protected by law.
8. The deadline is fixed
From 18 February 2027, every LMT battery, electric vehicle battery and industrial battery above 2 kWh placed on the market needs a passport (Article 77(1)). Member States lay down penalties that are effective, proportionate and dissuasive (Article 93). Designing, building, testing and securing your own system takes time that is running short.
Not only for manufacturers
The passport obligation applies to everyone who places a battery on the EU market or puts it into service. That is often a business without its own IT department:
- Importers and brand owners of, for example, e-bike or home batteries, who must obtain the data from a factory outside the EU.
- Businesses that repurpose, re-use or remanufacture batteries: they become responsible for a new passport linked to the original one (Article 77(7)).
- Producers and producer responsibility organisations: when a battery becomes waste, responsibility passes to them or to the selected waste management operator (Article 77(7)).
For these businesses the battery passport is an obligation next to their actual work. Developing and running a system of their own for years is rarely in proportion to their core activity.
“I already have the data.” So why not do it myself?
Perhaps you already hold the data: specifications, test reports, serial numbers. That is a good start, but data is not yet a battery passport. To become one, that data must:
- be linked, per individual battery, to a unique identifier and QR code complying with the ISO/IEC 15459 series or their equivalent (Article 77(3)), worked out in EN 18219 and EN 18220;
- be organised by the information in Annex XIII, based on open standards, machine-readable, structured and searchable (Article 77(5));
- be restricted per audience: public, legitimate interest or authorities only (Article 77(2));
- stay online and up to date until the battery is recycled, even if your company ceases (Article 77(8) and Article 78, point (e)).
That is where the work lies, and where we help. AccuZegel is data-driven: we publish an open battery passport data model and apply the standards for identifiers, such as GTIN with serial number through GS1 Digital Link, and for the QR code. We also read the technical documentation of batteries, such as the degree of protection of the enclosure against dust and water (the IP Code under IEC 60529, for example IP65). That rating is not required information under Annex XIII, but it is part of understanding your product. Your existing data does not have to be entered again: we make it fit for the passport.
You supply it securely through the AccuZegel portal, with sign-in using a second factor and defined roles per organisation, or through the API with public documentation. You remain the owner of your data, and a service provider may not re-use it (Article 78, point (d)). The portal is available to organisations we invite; new companies join the waiting list first.
What costs are involved?
A fair cost comparison depends on your number of models and batteries, the data your supplier already holds and the lifetime of your batteries. That is why this page names no amounts. You can, however, check who carries each cost item:
| Cost item | In-house | Outsourced |
|---|---|---|
| Designing, building and maintaining the system: data model, access rights, QR code and identifier | Development, then ongoing application maintenance and cybersecurity, internal or contracted | Part of the intended service |
| Hosting, backups and monitoring until the battery is recycled | Ongoing, for years | Recurring fee |
| Security, updates and incidents | Ongoing, own staff or supplier | Part of the intended service |
| Implementing new rules, standards and changes to Annex XIII | New development each time | Part of the intended service |
| Continuity if your company ceases or is taken over | Arrange and pay yourself | To be agreed in the contract |
| Requesting data from suppliers | Own time | Supported, but you supply |
| Checking and confirming data | Own time | Own time: remains your responsibility |
AccuZegel has no public prices yet; you receive a proposal with scope and fee before any engagement starts.
When does in-house make sense?
Doing it yourself can suit a large manufacturer with its own IT department, its own security organisation and a long-term continuity arrangement, already applying the European standards for product passports. Even then, the question remains how the passport stays available after a takeover or when activities end.
What remains your responsibility?
Outsourcing does not move the legal responsibility. The economic operator placing the battery on the market ensures that the information is accurate, complete and up to date (Article 77(4); recital 125). Agree in writing who supplies, checks and confirms data, and how the data stays available when the cooperation ends.
Who is responsible: manufacturer, importer or service provider?Questions for your provider about hosting and continuity
How AccuZegel handles this
AccuZegel, a trade name of DataChanges B.V., prepares and manages battery passports: collecting data from the factory, preparing the passport and QR code, hosting, updating and following new rules. You check and confirm the final data yourself. Published passports are recorded in DPPDir, a separate register for looking up product passports; it is not the official EU registry.
The application is in development. Retention, availability, transfer and the scope of management are agreed per customer before any engagement starts.
Frequently asked questions about outsourcing
Can I outsource the battery passport?
Yes. Article 77(4) of Regulation (EU) 2023/1542 allows the economic operator to give written authorisation to any other operator to act on its behalf, and Article 78, point (c), expressly mentions storage by such authorised operators. The legal responsibility for accurate, complete and up-to-date information stays with the economic operator placing the battery on the market.
Do I have to build a decentralised system myself?
No. Recital 126 says the battery passport should be based on a decentralised data system set up and maintained by economic operators. This means there is no central EU database holding every passport: each economic operator stores its own data, itself or through an authorised operator. No specific technology such as blockchain is prescribed.
How long must a battery passport remain available?
The battery passport ceases to exist only after the battery has been recycled (Article 77(8)). It must also remain available after the responsible economic operator ceases to exist or ceases its activity in the Union (Article 78, point (e)). The Regulation sets no fixed number of years; the life of the battery decides.
I already have the data. Why not do it myself?
Having the data is not the same as having a battery passport. The passport requires, per battery, a unique identifier and QR code complying with the ISO/IEC 15459 series or their equivalent, Annex XIII information in an open, machine-readable format, access rights per audience and availability until recycling (Articles 77 and 78). A service provider turns your existing data into that passport, so you do not have to enter anything again.
May a service provider use my battery data?
Not beyond what the service needs. Under Article 78, point (d), an authorised operator may not sell, re-use or process passport data, in whole or in part, beyond what is necessary for the storing or processing service.
Sources
- Regulation (EU) 2023/1542: recitals 125 and 126, Article 77, Article 78, Article 93 and Annex XIII.
- IEC 60529: degrees of protection provided by enclosures (IP Code).